| 300 SERIES UPS 10 to 80 Kva | |||||||
| MODEL |
310 |
315 | 320 | 330 | 340 | 360 | 380 |
| 10 | 15 | 20 | 30 | 40 | 60 | 80 | |
| INPUT | |||||||
| Voltage | 230/400 Vac 3 phase +N,+/-15% | ||||||
| By-pass Voltage | 230/400 Vac 3 phase, +/- 10% | ||||||
| Input frequency | 50 Hz ( 60 Hz on request ) +/- %5 | ||||||
| MAX RFI | EN50091-2 Class A. | ||||||
| Input out of tolerant protection | electronic input out of tolerant protection | ||||||
| OUTPUT | |||||||
| Power (kW) | 8 | 12 | 16 | 24 | 32 | 48 | 64 |
| Power factor |
0,8 |
||||||
| Voltage |
230/400 Vac 3 phase, +N |
||||||
| Voltage Stability |
(balanced load:+/-1%)(unbalanced load:+/-2%)(step load:+/-5% |
||||||
| Voltage recovery time |
After step load:Max.25ms. |
||||||
| Frequency |
50Hz (60Hz on request) |
||||||
| Frequency tolerance | (line synchronized:+/-2%) (free running:+/-0,2%) | ||||||
| Efficiency at 100% load | 89-91% | 90-92% | |||||
| Crest factor | 3:1 | ||||||
| Overload protection | (100%125% load :10 min ) (125%150% load :1 min ) (>150% load :by pass) | ||||||
| Short circuit protection | Electronic short circuit protection | ||||||
| Voltage out of tolerant protection | Electronic out of tolerant protection | ||||||
| Total harmonic distortion (THD) | Linear load: <3% | ||||||
| (THD) | Non Linear Load: <5% | ||||||
| BATTERIES | |||||||
| MODEL |
310 |
315 | 320 | 330 | 340 | 360 | 380 |
| Type | Sealed Lead Acid - Maintenance free | ||||||
| Number of Batteries | 30 | ||||||
| Float Charging Voltage | 405 VDC | ||||||
| End of discharge voltage | 300 VDC | ||||||
| Ambient temperature C | 25 C | ||||||
| Battery protection | Automatic circuit breaker | ||||||
| Battery out of tolerant protection | Electronic battery out of tolerant protection | ||||||
| Battery test | Automatic every 72 hours | ||||||
| GENERAL | |||||||
| Human interface | 2x16 character LCD panel | ||||||
| Communication | RS232+DRY contacts | ||||||
| Serial communication |
Dry contacts & RS232 |
||||||
| Software |
T-Mon UPS Management Software (3 clients standart) |
||||||
| Overtemperature protection | Electronic overtemperature protection | ||||||
| Temperature range | 0 C - 40 C | ||||||
| Ventilation | Forced air cooling | ||||||
| Relative humidity(non condensed) | < 90% (non condensed) | ||||||
| Protection degree | IP20 | ||||||
| Altitude | < 1000 m above sea level | ||||||
| Acoustic noise | <56dBA | <60dBA | |||||
| Weight without Batteries (kg) | 235 | 250 | 266 | 322 | 484 | 562 | 620 |
| Dimensions (mm) HxWxD | 1145x485x675 | 1400x570x820 |
1400x 710x800 |
||||
| OPTIONS | |||||||
| Input transformer | Galvanic isolation transformer at the input (in the external cabinet) | ||||||
| Input THD * | <10%(with 18 Pulse Rectifier ,according to UPS range | ||||||
| 5% (with 18 Pulse rectifier, + filter) upto 80 kVA | |||||||
| Input Power Factor * | 0.95 - 0.98 (with 18 Pulse rectifier) | ||||||
| MBS | Maintenance by-pass switch for complete isolation (For 206,207 & 210) | ||||||
| Parallel operation | 1+3 Systems (N+1 redundant, reduntant, symetric parallel) | ||||||
| (*): | In 18 pulse applications, the standard chasis dimensions may change. | ||||||
| ACCESSORIES | |||||||
| Monitoring and control software | TMON 3 clients standart | ||||||
| LCD Remote monitoring panel | Available as option | ||||||
| Graphical remote monitoring panel | Available as option | ||||||
| Multiserver shutdown unit | Available as option | ||||||
| SNMP communication adaptor | Available as option | ||||||
| MODBUS communication adaptor | Available as option (over RS485 or over TCP/IP) | ||||||
| Serial Port enhancer | Available as option | ||||||
| Long distance RS232/485 adaptor | Available as option | ||||||
![]() |
![]() |